Accupulse - NIBP Simulator
An ultimate NIBP test solution for all Blood Pressure Machines.

An affordable NIBP Simulator.
AccuPulse
, the ultimate NIBP Simulator is designed for  evaluating and testing of all non-invasive blood pressure monitors.

Accupulse is the only battery-powered and portable NIBP Simulator, half the size and weight of other NIBP Simulators.

Accupulse - This tiny NIBP Simulator, also provides built-in adult and neonate mandrels, eliminating the need to bring along "blocks" to test blood pressure monitors.

This second generation SmartArm, NIBP Simulator includes features suggested by hospital biomedical departments and industry R&D departments.


Features:
  • Auscultatory NIBP simulation 
  • Internal pump for static calibration, leak tests and over-pressure tests.
  • Independent systolic and diastolic pressures 
  • High resolution (5 msec sampling) cuff and pulse pressure 
  • Waveform display with scrolling and variable zoom.
Back to top
Specifications:
  • Programmed Peripheral Pulse Waveforms:
  • Pulse Amplitude @ MAP: 2.0 mmHg (nominal adult value)
  • Pulse Volume range: 0 to 4.4 ml 
  • Pulse Rise Time: 80 msec (minimum 
  • Heart Rate Presets: Adult 75 BPM, Neo 120 BPM
  • 1 BPM steps via Serial Remote 
  • Heart Rate Accuracy: ± 1 % of selected rate
  • Displayed Graphics:
  • Dynamic Real-Time NIBP Cuff Pressure Waveform
  • Programmed peripheral pulse waveform
  • Envelope waveform
  • Displayed Real-Time Parameters:
  • Instantaneous Cuff Pressure: 0.0 to 410 mmHg
  • Peak Cuff Pressure: 0.0 to 410 mmHg peak
  • Inflate / Deflate Time: 0.1 to 999.9 secs
  • Inflate / Deflate Time: 0.1 to 999.9 secs
  • Inflate / Deflate Rate: 0.1 to 999.9 mmHg/sec
  • Total Measurement Time: 0.0 to 999.9 secs max
  • Digital Manometer:
  • Pressure Range: 0.0 w 410 mmHg
  • Measurement Parameters: Instantaneous and Peak
  • Input Overpressure Limit: ±1500 mmHg
  • Accuracy: ±0.5 mmHg, traceable to NIST (NBS)
  • Standard Resolution: ±0.1 mmHg